Dashboard
/
identification_materials
/
Edit #13856
Edit row #13856 in
identification_materials
id
INTEGER ·
required
Auto-generated
job_id
INTEGER ·
required
picker_id
INTEGER ·
required
source_type
VARCHAR(13) ·
required
match_type
VARCHAR(13) ·
required
match_status
VARCHAR(6) ·
required
qr_code_string
VARCHAR(120) ·
required
storage_qr_string
VARCHAR(200) ·
required
storage_label
VARCHAR(200) ·
required
nameplate_image_path
VARCHAR(300)
equipment_image_path
VARCHAR(300)
extraction_status
VARCHAR(30)
extraction_result
JSON
{"manufacturer": "Honeywell Analytics", "equipment_type": "Universal Transmitter", "model_number": "XNX-BTAV-NNXBN", "serial_number": "44265457", "part_number": null, "tag_number": null, "equipment_description": "XNX Universal Transmitter for use in Class I, Div 1 Groups B, C & D Class I Zone 1, Groups IIB+H2 Haz Loc. Tamb -40 \u00b0C to 65 \u00b0C Temp Code T4. UL Classified Only as to Explosion, Fire, Electrical Shock Hazard. XNX-BT*Ex****** XNX-BT*-H* provide IS Circuitry /Assoc. Appt Per 1226E0454 CD & Manual Uin=250V. Contact Ratings: 250 VAC 5A, 24VDC 5A Resistive Loads Only. Class 2 Supply Req'd to 32 Vcc/DC Max. IIB+H2 T4 (Tamb=-40\u00b0C to 65\u00b0C) IP66. BR-EX d. INMETRO OCP 0016 ATEX 1272X-X. ATEN\u00c7\u00c3O: N\u00c3O ABRA QUANDO ENERGIZADO OU N\u00c3O ABRA ONDE UMA ATMOSFERA EXPLOSIVA POSSA ESTAR PRESENTE.", "visible_text": ["ZELL", "AMBIENTAL", "11-2107-2555", "zell@zell.com.br", "Calibra\u00e7\u00e3o", "Data Calib.", "11/05", "O.S.", "40003", "35YL", "UL CLASSIFIED", "XNX-BTAV-NNXBN SN: 44265457", "XNX Universal Transmitter for use in Class I, Div 1 Groups B, C & D", "Class I Zone 1, Groups IIB+H2 Haz Loc. Tamb -40 \u00b0C to 65 \u00b0C Temp Code T4", "Only as to Explosion, Fire, Electrical Shock Hazard", "XNX-BT*Ex****** XNX-BT*-H* provide IS Circuitry /Assoc.", "Appt Per 1226E0454 CD & Manual Uin=250V", "XNX-BT****** Contact Ratings: 250 VAC", "Mfg by: Honeywell Analytics, Inc. 415 Barclay Blvd.", "to 32 Vcc/DC Max.", "IIB+H2 T4 (Tamb=-40\u00b0C to 65\u00b0C) IP66", "BR-EX d", "Seguran\u00e7a", "INMETRO OCP 0016", "ATEX 1272X-X", "ATEN\u00c7\u00c3O: N\u00c3O ABRA QUANDO", "ENERGIZADO OU N\u00c3O ABRA ONDE UMA", "ATMOSFERA EXPLOSIVA POSSA ESTAR", "PRESENTE", "250 VAC 5A, 24VDC 5A Resistive Loads Only", "Lincolnshire, IL 60069 USA", "Class 2 Supply Req'd", "XNX UNIVERSAL TRANSMITTER"]}
extraction_retries
INTEGER ·
required
matched_iadc_material_id
INTEGER
matched_spare_material_id
INTEGER
match_confidence
DOUBLE PRECISION
match_details
JSON
material_id
INTEGER
cross_reference_id
VARCHAR(50)
manual_selected_name
VARCHAR(200)
notes
TEXT
created_at
TIMESTAMP ·
required
updated_at
TIMESTAMP ·
required
is_active
BOOLEAN ·
required
True
False
disposition
VARCHAR(50) ·
required
admin_notes
TEXT
[auto-publish: new_material]
admin_status
VARCHAR(20) ·
required
reviewed_by
INTEGER
reviewed_at
TIMESTAMP
condition
VARCHAR(20)
grade
VARCHAR(30)
nameplate_image_paths
JSON
["yard/117/images/nameplate_117_20260831093246095306_814.jpg", "yard/117/images/nameplate_117_20260831093246095648_eb5.jpg"]
equipment_image_paths
JSON
["yard/117/images/equipment_117_20260831093246095949_721.jpg"]
origin
VARCHAR(20) ·
required
Cancel